In this paper, a new calibration method with two-filling factors for the permittivity measurement is proposed. With this calibration method, it is not necessary to measure the volume of the small sample, which not only eliminates the measurement error of the sample volume, but also simplifies the measurement procedure. To improve the measurement accuracy, the Cursor method, the resonance curve area (RCA) method and the Lorentzian fit method are utilized to process the measured resonant curve data so as to obtain accurate resonant frequency and quality factor. Finally, the obtained permittivity measurement results of a liquid sample validate the accuracy of this permittivity measurement approach.
Yan YeTaijun LiuXingbin ZengJiaming HeCevdet Akyel
Himanshu PrakashSurya Pal Singh
Qian ChenYang YangKa Ma HuangCheng ChenKai Yong Wang