The design and construction of a high-temperature wire strain gage for measuring turbine rotor blade vibrations are discussed. The discussion includes wire size, types of bonding cements, bonding procedure, calibration, and turbine installation. A description of the equipment used to investigate the turbine rotor blade vibrations under actual engine running conditions is given. (C.J.G.)