JOURNAL ARTICLE

Transfer of Tactile Sensors Using Stiction Effect Temporary Handling

Peng ZhongKe SunChaoyue ZhengHeng YangXinxin Li

Year: 2021 Journal:   Micromachines Vol: 12 (11)Pages: 1330-1330   Publisher: Multidisciplinary Digital Publishing Institute

Abstract

A novel method for transfer of tactile sensors using stiction effect temporary handling (SETH) is presented to simplify the microelectromechanical-system (MEMS)/CMOS integration process, improve the process reliability and electrical performance, and reduce material constriction. The structure of the tactile sensor and the reroute substrate were first manufactured separately. Following the release process, the stiction-contact structures, which are designed to protect the low-stress silicon nitride diaphragm of the tactile sensor and prevent the low-stress silicon nitride diaphragm from moving during the subsequent bonding process, are temporarily bonded to the substrate owing to the stiction effect. After the released tactile sensor is bonded to the reroute substrate by Au–Si eutectic flip-chip bonding, a pulling force perpendicular to the bonded die is applied to break away the temporary supported beam of the tactile sensor, and the tactile sensor is then successfully transferred to the reroute substrate. The size of the transferred tactile sensor is as small as 180 μm × 180 μm × 1.2 μm, and the force area of the tactile sensor is only 120 μm × 120 μm × 1.2 μm. The maximum misalignment of the flip-chip bonding process is approximately 1.5 μm. The tactile sensors are tested from 0 to 17.1 kPa when the power supply is 5 V, resulting in a sensitivity of 0.22 mV/V/kPa, 0.26 mV/V/kPa, 0.27 mV/V/kPa and 0.27 mV/V/kPa, separately. The stress caused by the Au–Si eutectic flip-chip bonding ranges from −5.83 to +5.54 kPa. The temporary bonding strength caused by stiction is calculated to be larger than 7.06 kPa and less than 22.31 kPa. The shear strength of the bonded test structure is approximately 30.74 MPa and the yield of the transferred tactile sensors is as high as 90%.

Keywords:
Stiction Tactile sensor Tactile display Materials science Automotive engineering Computer science Artificial intelligence Engineering Nanotechnology Microelectromechanical systems Robot

Metrics

1
Cited By
0.09
FWCI (Field Weighted Citation Impact)
35
Refs
0.39
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Citation History

Topics

Advanced Sensor and Energy Harvesting Materials
Physical Sciences →  Engineering →  Biomedical Engineering
Tactile and Sensory Interactions
Life Sciences →  Neuroscience →  Cognitive Neuroscience
Interactive and Immersive Displays
Physical Sciences →  Computer Science →  Human-Computer Interaction

Related Documents

JOURNAL ARTICLE

Tactile Sensors for Robot Handling

Farzin ForoughiHomer RahnejatH. Bera

Journal:   Proceedings of the Institution of Mechanical Engineers Part B Management and engineering manufacture Year: 1987 Vol: 201 (1)Pages: 51-58
JOURNAL ARTICLE

Robots’ Handling Objects with Slip Sensors and Triaxial Tactile Sensors

Shizuka TakahashiIkuo Mizuuchi

Journal:   The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec) Year: 2018 Vol: 2018 (0)Pages: 1P1-L18
© 2026 ScienceGate Book Chapters — All rights reserved.