JOURNAL ARTICLE

Energy window optimization for Y-90 Bremsstrahlung SPECT imaging: A Monte Carlo simulation study

Hicham AsmiFarida BentayebYoussef BouzekraouiFaustino BonuttiSanae Douama

Year: 2020 Journal:   DOAJ (DOAJ: Directory of Open Access Journals) Vol: 18 (4)Pages: 263-269

Abstract

Introduction: In yttrium-90 imaging, image quality is highly dependent on the selection of energy window and collimator design becausetheY-90 bremsstrahlung photons have a continuous and broad energy distribution. The current study aimed to optimize the bremsstrahlung energy window setting and collimator for the improvement of both resolution and sensitivity. Material and Methods: In the present study, simulation of medical imaging nuclear detectors (SIMIND) Monte Carlo program was used to simulate Siemens Medical System Symbia. The SIMIND was utilized to generate the Y-90 bremsstrahlung single-photon emission computed tomography (SPECT) projection of the point source. Six energy windows settings and two collimators denoting medium energy and high energy were used in order to assess the effect of the energy window on the resolution. Results: The experimental measurements and simulation results showed a similar pattern in the point spread functions with the energy window. The simulation data indicated that the geometric component reached 73%for the energy window within the range of51-120keVusingthe high-energy (HE) collimator. In addition, the obtained results showed that the full width at half maximum (FWHM) and full width at tenth maximum (FWTM)(FWHM=7mm and FWTM=35mm)were higher in this window in comparison to those reported for other windows. Conclusion: According to the obtained results of the present study, the optimal energy window for Y-90 bremsstrahlung SPECT imaging was within the range of 51-120 keV. The obtained optimal energy window and optimal HE collimator had the potential to improve the image resolution and sensitivity of Y-90 SPECT images

Keywords:
Collimator Bremsstrahlung Monte Carlo method Physics Spect imaging Full width at half maximum Point source Energy (signal processing) Photon energy Image resolution Optics Imaging phantom Photon Resolution (logic) Nuclear medicine Computer science Mathematics Statistics Medicine Artificial intelligence

Metrics

0
Cited By
0.00
FWCI (Field Weighted Citation Impact)
0
Refs
0.06
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Topics

Medical Imaging Techniques and Applications
Health Sciences →  Medicine →  Radiology, Nuclear Medicine and Imaging
Advanced X-ray and CT Imaging
Physical Sciences →  Engineering →  Biomedical Engineering
Radiomics and Machine Learning in Medical Imaging
Health Sciences →  Medicine →  Radiology, Nuclear Medicine and Imaging

Related Documents

JOURNAL ARTICLE

Monte Carlo Simulation of /sup 90/Y Bremsstrahlung Imaging

Sarah HeardGlenn FluxMatthew GuyR.J. Ott

Journal:   IEEE Symposium Conference Record Nuclear Science 2004. Year: 2005 Vol: 6 Pages: 3579-3583
JOURNAL ARTICLE

Collimator and energy window optimization for YTTRIUM-90 bremsstrahlung SPECT imaging

Caner İnceÖzlem KaradenizTürkan ErtayHatice Durak

Journal:   Applied Radiation and Isotopes Year: 2020 Vol: 167 Pages: 109453-109453
BOOK-CHAPTER

Optimization of Yttrium-90 Bremsstrahlung Imaging with Monte Carlo Simulations

Erwann RaultStefaan VandenbergheSteven StaelensIgnace Lemahieu

World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany Year: 2009 Pages: 500-504