JOURNAL ARTICLE

Reliability of the Dexcom G6 Continuous Glucose Monitor During Hyperbaric Oxygen Exposure

Enoch HuangShaban DemirelChanelle BlissDavut SavaserJessica R. Castle

Year: 2020 Journal:   Diabetes Technology & Therapeutics Vol: 22 (5)Pages: 360-366   Publisher: Mary Ann Liebert, Inc.

Abstract

Background: People with diabetes-related ulcers may benefit from hyperbaric oxygen (HBO2) therapy and from continuous glucose monitors (CGM). Although blood glucose (BG) meters based on glucose oxidase (GO) report erroneously low values at high pO2, BG meters based on glucose dehydrogenase (GD) do not. We therefore examined the performance of a GO-based CGM system in comparison to GO-based and GD-based BG systems in normobaric air (NBAir), hyperbaric air (HBAir), and HBO2 environments. Materials and Methods: Twenty-six volunteers without diabetes mellitus (DM) wore Dexcom G6 CGM systems and provided periodic blood samples before, during, and after a standard HBO2 treatment consisting of three 30-min intervals of HBO2 separated by two 5-min intervals of HBAir. Accuracy of the CGM and GO-based BG meter were assessed by comparisons with the GD-based values. Results: The mean absolute relative difference for the CGM system was 15.96% and for the GO-based meter was 8.52%. Compared to NBAir, HBO2 exposure resulted in significantly higher CGM values (+3.76 mg/dL, P < 0.001) and significantly lower GO-based meter values (-10.38 mg/dL, P < 0.001). Pre-HBO2 and post-HBO2 values obtained in NBAir were also significantly different when measured by CGM (+4.13 mg/dL, P = 0.015) or the GO-based meter (-9.04 mg/dL, P < 0.001). Conclusions: In volunteers without DM, HBO2 exposure results in statistically significant differences in glucose measurements obtained with GO-based devices, but not a GD-based device. Standard HBO2 treatment results in statistically significant effects on glucose concentrations. These differences are of unlikely clinical significance.

Keywords:
Medicine Hyperbaric oxygen Continuous glucose monitoring Reliability (semiconductor) Diabetes mellitus Oxygen Type 1 diabetes Anesthesia Endocrinology Thermodynamics Physics

Metrics

3
Cited By
0.36
FWCI (Field Weighted Citation Impact)
22
Refs
0.57
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Citation History

Topics

Hyperglycemia and glycemic control in critically ill and hospitalized patients
Health Sciences →  Medicine →  Endocrinology, Diabetes and Metabolism
Diabetes Management and Research
Health Sciences →  Medicine →  Endocrinology, Diabetes and Metabolism
Cardiovascular Function and Risk Factors
Health Sciences →  Medicine →  Cardiology and Cardiovascular Medicine

Related Documents

JOURNAL ARTICLE

Dexcom Continuous Glucose Monitor Receivers

Journal:   Biomedical Safety & Standards Year: 2025 Vol: 55 (17)Pages: 95-95
JOURNAL ARTICLE

Dexcom Continuous Glucose Monitoring Systems

Journal:   Biomedical Safety & Standards Year: 2016 Vol: 46 (11)Pages: 83-83
JOURNAL ARTICLE

Vascular effects of continuous hyperbaric oxygen exposure

Celal YavuzOğuz KarahanÖzgür Akkaya

Journal:   Medical Gas Research Year: 2022 Vol: 13 (4)Pages: 198-201
© 2026 ScienceGate Book Chapters — All rights reserved.