JOURNAL ARTICLE

Closed-Loop Interstitial Fluid Sensing Continuous Glucose Monitor

Wesley Hood

Year: 2021 Journal:   OPAL (Open@LaTrobe) (La Trobe University)   Publisher: La Trobe University

Abstract

At present, the food and drug administration (FDA) has not approved any fully implantable continuous glucose monitors (CGMs). Currently, diabetes patients cannot adjust the insulin dose their body needs solely based on readings made from CGMs. The FDA has only approved the use of CGMs as supplements, not replacements, to home blood glucose meters that require a small blood sample from a finger prick. Current CGMs that are in the market today have sensors that have to be replaced every three to seven days depending on the manufacturer. This has increased the work load associated with maintaining glucose levels as close to normal as possible. My senior design project aims to reduce the amount of work required by the patient and implement a fully closed-loop system to allow for insulin delivery without patient assistance. The product I designed is a closed-loop interstitial fluid (ISF) CGM. The glucose sensor will be placed in the ISF and will have a lifetime of a year or greater. Patients' smartphones will be the computer receiving the reading from the glucose sensor. This reading along with patient inputs will allow the computer to decide the proper amount of insulin needing to be delivered and send that to the insulin delivery system. The insulin deliver system will then deliver the proper amount of insulin without patient assistance. These three separate devices will be connected through Bluetooth. My product will make the lives of diabetic patients much easier and has the possibility of making their expenses considerably less.

Keywords:
Continuous glucose monitoring Interstitial fluid Closed loop Loop (graph theory) Computer science Control theory (sociology) Mathematics Internal medicine Medicine Artificial intelligence Control (management) Control engineering Engineering Insulin Glycemic Combinatorics

Metrics

0
Cited By
0.00
FWCI (Field Weighted Citation Impact)
0
Refs
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Topics

Electrochemical sensors and biosensors
Physical Sciences →  Engineering →  Electrical and Electronic Engineering
Analytical Chemistry and Sensors
Physical Sciences →  Chemical Engineering →  Bioengineering
Microfluidic and Capillary Electrophoresis Applications
Physical Sciences →  Engineering →  Biomedical Engineering

Related Documents

JOURNAL ARTICLE

Calibration algorithms for continuous glucose monitoring systems based on interstitial fluid sensing

Tianyi SunJen‐Tsai LiuC. Chen

Journal:   Biosensors and Bioelectronics Year: 2024 Vol: 260 Pages: 116450-116450
JOURNAL ARTICLE

Susceptibility of Interstitial Continuous Glucose Monitor Performance to Sleeping Position

Brett D. MenshNatalie WisniewskiBrian M. NeilDaniel Burnett

Journal:   Journal of Diabetes Science and Technology Year: 2013 Vol: 7 (4)Pages: 863-870
JOURNAL ARTICLE

Closed Loop Polarimetric Glucose Sensing Using The Pockels Effect

Timothy W. KingCote

Journal:   Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Year: 1992 Pages: 161-162
© 2026 ScienceGate Book Chapters — All rights reserved.