JOURNAL ARTICLE

Determination of high concentration of glucose by flow injection analysis with immobilized enzyme tube reactor.

Shunichi UchiyamaYoshinobu TohfukuShuichi SuzukiGiichi MUTÔ

Year: 1986 Journal:   BUNSEKI KAGAKU Vol: 35 (2)Pages: 134-136   Publisher: Japan Society for Analytical Chemistry

Abstract

Glucose oxidase (G.O., E.C.1.1.3.4) was immobilized into polyacrylamide gel tube (i.d., 3 mm) and a flow injection system with this tube reactor was fabricated to allow the determination of high concentration of glucose and to extend a linear range of the calibration curve. A Sample solution was passed through the tube reactor, and hydrogen peroxide produced by the enzyme reaction (1) was electro chemically oxidized on a platinum wire electrode at +0.6 V vs. SCE.Glucouse G.O. → Gluconic acid + H2O2 ……… ( 1 ) The peak height of the current was proportional to the concentration of glucouse. The linear range of the calibration curve could be extended by varying either sample flow rate or sample volume, and 5 × 10-4 2 M glucose could be determined directly. The relative standard deviation was about 2%. The time reguired for the analysis of each sample was about 2 min, where sample flow rate was 8.4 ml/min and sample volume was 5 pi. The half life of the immobilized enzyme activty was about one month and more than fifteen hundreds samples could be determined by the same immobilized enzyme tube reactor.

Keywords:
Glucose oxidase Calibration curve Chemistry Chromatography Gluconic acid Hydrogen peroxide Immobilized enzyme Flow injection analysis Volumetric flow rate Platinum Analytical Chemistry (journal) Volume (thermodynamics) Electrode Detection limit Enzyme Catalysis Biochemistry

Metrics

1
Cited By
0.00
FWCI (Field Weighted Citation Impact)
0
Refs
0.26
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Topics

Electrochemical sensors and biosensors
Physical Sciences →  Engineering →  Electrical and Electronic Engineering
Analytical Chemistry and Sensors
Physical Sciences →  Chemical Engineering →  Bioengineering
Water Quality Monitoring and Analysis
Physical Sciences →  Environmental Science →  Industrial and Manufacturing Engineering

Related Documents

JOURNAL ARTICLE

Flow Injection Analysis for Amperometric Detection of Glucose with Immobilized Enzyme Reactor

Ruska NenkovaR. AtanasovaD. IvanovaTzonka Godjevargova

Journal:   Biotechnology & Biotechnological Equipment Year: 2010 Vol: 24 (3)Pages: 1986-1992
JOURNAL ARTICLE

Micro-scale determination of glucose by capillary flow injection with an immobilized enzyme reactor

Yi ShiStanley R. Crouch

Journal:   Analytica Chimica Acta Year: 1999 Vol: 381 (2-3)Pages: 165-173
JOURNAL ARTICLE

Spectrophotometric determination of glucose in foods by flow injection analysis with an immobilized glucose oxidase reactor

Shi Ren-bingKathrin SteinGeorg Schwedt

Journal:   Zeitschrift für Lebensmittel-Untersuchung und -Forschung. B, Referate und Lebensmittelrecht Year: 1997 Vol: 204 (2)Pages: 99-102