JOURNAL ARTICLE

New Islanding Detection Method for Inverter-Based Distributed Generation Considering Its Switching Frequency

Abstract

Islanding detection is one of the most important issues for distributed generation (DG) systems connected to an electric power grid. The conventional passive islanding detection methods inherently have a non-detection zone (NDZ), and active islanding detection methods might cause problems with safety, reliability, stability, and power quality on power system. This paper proposes a passive islanding detection method with the zero NDZ property by considering the switching frequency of an inverter of the DG system. Moreover, the proposed method does not cause any negative effects in the above problems because it avoids applying the intended changes such as variations of reactive power and/or harmonics, which are required in the active islanding detection methods. Several case studies are carried out to verify that the proposed method can detect the islanding operation within 20 milliseconds, which is less than 150 milliseconds required in a recloser as the shortest mechanical reclosing (delay) time. This value also satisfies the requirement of 2 seconds given in the IEEE Std. 1547.

Keywords:
Islanding Inverter Harmonics Distributed generation AC power Computer science Electronic engineering Reliability (semiconductor) Power (physics) Control theory (sociology) Voltage Recloser Engineering Circuit breaker Electrical engineering Physics

Metrics

6
Cited By
0.27
FWCI (Field Weighted Citation Impact)
18
Refs
0.67
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Citation History

Topics

Islanding Detection in Power Systems
Physical Sciences →  Engineering →  Electrical and Electronic Engineering
Power Systems Fault Detection
Physical Sciences →  Engineering →  Control and Systems Engineering
Microgrid Control and Optimization
Physical Sciences →  Engineering →  Control and Systems Engineering

Related Documents

JOURNAL ARTICLE

New Islanding Detection Method for Inverter-Based Distributed Generation Considering Its Switching Frequency

Soo Hyoung LeeJung-Wook Park

Journal:   IEEE Transactions on Industry Applications Year: 2010 Vol: 46 (5)Pages: 2089-2098
JOURNAL ARTICLE

Islanding detection of inverter-based distributed generation

Hatem ZeineldinEhab F. El‐SaadanyM.M.A. Salama

Journal:   IEE Proceedings - Generation Transmission and Distribution Year: 2006 Vol: 153 (6)Pages: 644-644
JOURNAL ARTICLE

Islanding Detection Method for Multi-Inverter Distributed Generation

Alben CardenasKodjo AgbossouMamadou Lamine Doumbia

Journal:   Journal of Electromagnetic Analysis and Application Year: 2009 Vol: 01 (03)Pages: 170-180
JOURNAL ARTICLE

A Novel Islanding Detection Method for Inverter-Based Distributed Generation Systems

Dong XieXing Zhang

Journal:   Applied Mechanics and Materials Year: 2013 Vol: 318 Pages: 597-600