JOURNAL ARTICLE

Experimental study of high frame rate imaging with limited diffraction beams

Jian-yu Lu

Year: 1998 Journal:   IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control Vol: 45 (1)Pages: 84-97   Publisher: Institute of Electrical and Electronics Engineers

Abstract

Limited diffraction beams have a large depth of field and have many potential applications. Recently, a new method (Fourier method) was developed with limited diffraction beams for image construction. With the method and a single plane wave transmission, both 2D (two-dimensional) and 3D (three-dimensional) images of a very high frame rate (up to 3750 frames/s for a depth of 200 mm in biological soft tissues) and a high signal-to-noise ratio (SNR) can be constructed with relatively simple and inexpensive hardware. If limited diffraction beams of different parameters are used in both transmission and reception and transducer aperture is shaded with a cosine function, high-resolution and low-sidelobe images can be constructed with the new method without montage of multiple frames of images [the image quality is comparable to that obtained with a transmit-receive (two-way) dynamically focused imaging system]. In this paper, the Fourier method was studied with both experiment and computer simulation for 2D B-mode imaging. In the experiment, two commercial broadband 1D array transducers (48 and 64 elements) of different aperture sizes (18.288 and 38.4 mm) and center frequencies (2.25 and 2.5 MHz) were used to construct images of different viewing sizes. An ATS539 tissue-equivalent phantom of an average frequency-dependent attenuation of 0.5 dB/MHz/cm was used as a test object. To obtain high frame rate images, a single plane wave pulse (broadband) was transmitted with the arrays. Echoes received with the arrays were processed with both the Fourier and conventional dynamic focusing (delay-and-sum) methods to construct 2D B-mode images. Results show that the quality (resolution and contrast) of constructed images is virtually identical for both methods, except that the Fourier method is simpler to implement. Both methods have also a similar sensitivity to phase aberration distortions. Excellent agreement among theory, simulation, and experiment was obtained.

Keywords:
Diffraction Optics Aperture (computer memory) Frame rate Imaging phantom Image quality Attenuation Fourier transform Plane wave Transducer Physics Acoustics Materials science Computer science Image (mathematics) Computer vision

Metrics

154
Cited By
3.89
FWCI (Field Weighted Citation Impact)
76
Refs
0.94
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Citation History

Topics

Optical Coherence Tomography Applications
Physical Sciences →  Engineering →  Biomedical Engineering
Advanced Fluorescence Microscopy Techniques
Life Sciences →  Biochemistry, Genetics and Molecular Biology →  Biophysics
Advanced X-ray Imaging Techniques
Physical Sciences →  Physics and Astronomy →  Radiation

Related Documents

JOURNAL ARTICLE

Extended high-frame rate imaging method with limited-diffraction beams

Jiqi ChengJian-yu Lu

Journal:   IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control Year: 2006 Vol: 53 (5)Pages: 880-899
JOURNAL ARTICLE

2D and 3D high frame rate imaging with limited diffraction beams

Jian-yu Lu

Journal:   IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control Year: 1997 Vol: 44 (4)Pages: 839-856
JOURNAL ARTICLE

High-frame-rate limited-diffraction beam imaging

Jian-yu Lu

Journal:   The Journal of the Acoustical Society of America Year: 2022 Vol: 152 (4_Supplement)Pages: A217-A218
JOURNAL ARTICLE

A Way to Improve the Efficiency of High Frame Rate Imaging Algorithm with Limited Diffraction Beams

Yong WeiHu Peng

Journal:   Applied Mechanics and Materials Year: 2013 Vol: 385-386 Pages: 1505-1508
© 2026 ScienceGate Book Chapters — All rights reserved.