In this paper, we present a procedure for switching on and off base stations (BSs) that are powered with solar panels and have finite batteries. In the scenario under consideration it is considered that the BSs are placed at the same site with fully overlapped coverage areas and using different frequencies. We propose a decision strategy where we assume perfect knowledge of the traffic profile and a second approach where a robust Bayesian strategy is considered in order to account for possible error modeling in the traffic profile information.
Eunsung OhKyuho SonBhaskar Krishnamachari
Mingjie FengShiwen MaoTao Jiang
Zhongming ZhengShibo HeLin CaiXuemin Shen
Alexandra BousiaElli KartsakliLuis AlonsoChristos Verikoukis