JOURNAL ARTICLE

<title>Performance and calibration of the AXAF High-Resolution Camera I: imaging readout</title>

Abstract

The high resolution camera (HRC) will be one of the two focal plane instruments on the Advanced X-ray Astrophysics Facility, (AXAF). AXAF will perform high resolution spectrometry and imaging in the X-ray band of 0.1 to 10 keV. The HRC instrument consists of two detectors, the HRC-I for imaging and the HRC-S for spectroscopy. Each HRC detector consists of a thin aluminized polyimide window, a chevron pair of microchannel plates (MCPs) and a crossed grid charge readout. The HRC-I is a 100 by 100 mm detector optimized for high resolution imaging and timing, the HRC-S is an approximately 30 by 300 mm detector optimized to function as the readout for the low energy transmission grating spectrometer (LETGS). In this paper we present the absolute quantum efficiency, spatial resolution, point spread response function and count rate linearity of the HRC-I detector. Data taken at the HRC laboratory and at the Marshall Space Flight Center X-ray Calibration Facility are presented. The development of the HRC is a collaborative effort between The Smithsonian Astrophysical Observatory, University of Leicester UK and the Osservatorio Astronomico, G.S. Vaiana, Palermo Italy.

Keywords:
Physics Detector Calibration Optics Observatory Spectrometer Resolution (logic) Microchannel plate detector Image resolution Cardinal point Astronomy Computer science

Metrics

5
Cited By
1.09
FWCI (Field Weighted Citation Impact)
11
Refs
0.78
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Citation History

Topics

Advanced X-ray Imaging Techniques
Physical Sciences →  Physics and Astronomy →  Radiation
Medical Imaging Techniques and Applications
Health Sciences →  Medicine →  Radiology, Nuclear Medicine and Imaging
X-ray Spectroscopy and Fluorescence Analysis
Physical Sciences →  Physics and Astronomy →  Radiation

Related Documents

JOURNAL ARTICLE

<title>High-Resolution Camera on AXAF</title>

A. KenterJohn H. ChappellRalph KraftG. R. MeehanS. S. MurrayMartin V. ZombeckG.W. Fraser

Journal:   Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE Year: 1996 Vol: 2808 Pages: 626-649
JOURNAL ARTICLE

<title>Calibration of the UV/ion shields for the AXAF High-Resolution Camera</title>

G. R. MeehanS. S. MurrayMartin V. ZombeckRalph KraftK. KobayashiJohn H. ChappellA. KenterMarco BarberaA. ColluraS. Serio

Journal:   Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE Year: 1997 Vol: 3114 Pages: 74-100
© 2026 ScienceGate Book Chapters — All rights reserved.