JOURNAL ARTICLE

Axial eye-length measurement by wavelength-shift interferometry

Akihiko SekineIsao MinegishiHiroshi Koizumi

Year: 1993 Journal:   Journal of the Optical Society of America A Vol: 10 (7)Pages: 1651-1651   Publisher: Optica Publishing Group

Abstract

A simplified noncontact measuring technique for axial eye length was developed. According to this method, the wavelength shift of a single-mode laser-diode beam that is irradiated onto the eyeball causes a phase shift in the interference fringes of reflections from the retina and the cornea. Then the optical distance between the cornea and the retina is obtained from the phase-shift measurement. High-speed axial eye-length measurements can be performed by using a laser diode on a pulse-modulation drive and signals from the reference light path as an analog-to-digital-conversion trigger. Compared with the technique that uses partially coherent light, this technique is inferior in terms of measurement accuracy but superior in its wide, measurable range of 16-32 mm. The results of measurements of 21 adults showed that 2 standard deviations of measurement was 2 sigma = +/- 0.11 mm.

Keywords:
Interferometry Optics Wavelength Length measurement Physics Materials science

Metrics

17
Cited By
1.64
FWCI (Field Weighted Citation Impact)
2
Refs
0.85
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Citation History

Topics

Optical measurement and interference techniques
Physical Sciences →  Computer Science →  Computer Vision and Pattern Recognition
Ophthalmology and Visual Impairment Studies
Health Sciences →  Medicine →  Epidemiology
Glaucoma and retinal disorders
Health Sciences →  Medicine →  Ophthalmology

Related Documents

JOURNAL ARTICLE

<title>Measurement of the axial eye length by wavelength-tuning interferometry</title>

Franz LexerChristoph K. HitzenbergerManfred KulhavyAdolf F. Fercher

Journal:   Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE Year: 1996 Vol: 2930 Pages: 202-206
JOURNAL ARTICLE

Measurement Reliability of Axial Length of the Human Eye by using Partial Coherence Interferometry

Jae‐Hyung KimTae Hwan MoonJu Byung ChaeSungmin Hyung

Journal:   Journal of the Optical Society of Korea Year: 2014 Vol: 18 (5)Pages: 546-550
JOURNAL ARTICLE

Ultrasound velocities for axial eye length measurement

Kenneth J. Hofer

Journal:   Journal of Cataract & Refractive Surgery Year: 1994 Vol: 20 (5)Pages: 554-562
© 2026 ScienceGate Book Chapters — All rights reserved.