JOURNAL ARTICLE

Vibration transducer using an ultrashort Fabry–Perot cavity

Norikatsu MioKimio Tsubono

Year: 1995 Journal:   Applied Optics Vol: 34 (1)Pages: 186-186   Publisher: Optica Publishing Group

Abstract

We report here on the development of an optical transducer for mechanical vibration, making use of an ultrashort Fabry-Perot cavity. The noise level measured by a cavity 150 µm long is ~1.3 × 10(-16) m/√Hz at ~1 kHz, which was obtained without a frequency-stabilization system. It was, however, large compared with the shot noise.

Keywords:
Fabry–Pérot interferometer Optics Transducer Vibration Materials science Noise (video) Acoustics Physics Laser

Metrics

15
Cited By
1.12
FWCI (Field Weighted Citation Impact)
25
Refs
0.76
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Topics

Advanced Frequency and Time Standards
Physical Sciences →  Physics and Astronomy →  Atomic and Molecular Physics, and Optics
Advanced Fiber Laser Technologies
Physical Sciences →  Physics and Astronomy →  Atomic and Molecular Physics, and Optics
Cold Atom Physics and Bose-Einstein Condensates
Physical Sciences →  Physics and Astronomy →  Atomic and Molecular Physics, and Optics

Related Documents

JOURNAL ARTICLE

Micromachined Fabry-Perot cavity pressure transducer

Y. KimDean P. Neikirk

Journal:   IEEE Photonics Technology Letters Year: 1995 Vol: 7 (12)Pages: 1471-1473
JOURNAL ARTICLE

Micromachined Fabry-Perot cavity pressure transducer with optical fiber interconnects

Young‐Min KimDean P. Neikirk

Journal:   Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE Year: 1995 Vol: 2642 Pages: 242-242
BOOK-CHAPTER

Fabry-Perot Cavity Antennas

Alexandros FeresidisKonstantinos KonstantinidisP. Gardner

Signals and communication technology Year: 2017 Pages: 221-241
© 2026 ScienceGate Book Chapters — All rights reserved.