JOURNAL ARTICLE

Ultrasound Attenuation Measurements of the Liver in Vivo Using a Commercial Sector Scanner

Brian S. GarraThomas H. ShawkerMenahem NassíMary Ann Russell

Year: 1984 Journal:   Ultrasonic Imaging Vol: 6 (4)Pages: 396-407   Publisher: SAGE Publishing

Abstract

Attenuation measurements of various tissue minicking phantoms and three different groups of patients were obtained using a modified commercial sector scanner. Estimates of attenuation were made using the spectral shift method with mean frequencies at different depths of a region of interest being obtained by both zero crossing and fast Fourier transform techniques. The accuracy and precision of both techiques was compared in phantoms and it was found that the FFT technique yielded less day-to-day variation (SD=3 percent) than the zero crossing technique (5 percent). For larger regions of interest, the range of variation in both techniques was more similar. Day-to-day variation in livers of normal patients was much larger than that seen in phantoms (10 to 15 percent) suggesting that in vivo measurements may be less precise due to actual daily changes in patients' livers. Attenuation estimates of phantoms were high by approximately 0.16 dB/Mllz/cm compared to values obtained by transmission techniques. The attenuation values of livers in a group of 31 normal patients ranged from 0.214 dB/cm/MHz to 0.849 dB/cm/MHz with a mean of 0.627 ± 0.126 dB/cm/MHz for the zero crossing technique while the mean value using the FFT technique was 0.86 ± 0.168 dB/cm/MHz. A group of 26 Gauchers disease patients also showed wide variation with a mean attenuation value of 0.768 ± 0.21 dB/cm/MHz using the FFT technique. This was significantly different than that of the normal group (p<.05). Also, a group of 22 chronic B hepatitis patients was examined, having a mean attenuation value of 0.823 ± 0.21 dB/cm/MHz, not significantly different from those of the normal patients. Highly significant differences were found between the three groups when the power spectrum bandwidths of signals received were compared. These differences may be due to differences in the dependence of attenuation as a function of frequency between the groups and may represent a useful tissue characterization parameter.

Keywords:
Ultrasound Attenuation Scanner Materials science In vivo Biomedical engineering Acoustics Radiology Medicine Optics Physics

Metrics

24
Cited By
1.12
FWCI (Field Weighted Citation Impact)
12
Refs
0.76
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Citation History

Topics

Liver Disease Diagnosis and Treatment
Health Sciences →  Medicine →  Epidemiology

Related Documents

JOURNAL ARTICLE

In-vivo measurements of ultrasound attenuation in normal or diseased liver

Kevin J. ParkerM. AsztélyR.M. LernerEric A. SchenkRobert C. Waag

Journal:   Ultrasound in Medicine & Biology Year: 1988 Vol: 14 (2)Pages: 127-136
JOURNAL ARTICLE

Dependence of CT attenuation values on scanner type using in vivo measurements

Mithun PrasadA Carrasco MezaHyun J. KimMatthew S. BrownFereidoun AbtinJonathan GoldinMichael F. McNitt‐Gray

Journal:   Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE Year: 2008 Vol: 6913 Pages: 69131K-69131K
JOURNAL ARTICLE

Relative Attenuation Measurements of Ultrasound in the Liver using the Zerocrossing Method

Knud-Erik Fredfeldt

Journal:   Acta Radiologica Year: 1989 Vol: 30 (3)Pages: 299-303
JOURNAL ARTICLE

Relative Attenuation Measurements of Ultrasound in the Liver Using the Zerocrossing Method

Knud-Erik Fredfeldt

Journal:   Acta Radiologica Year: 1989 Vol: 30 (3)Pages: 299-303
© 2026 ScienceGate Book Chapters — All rights reserved.