JOURNAL ARTICLE

Comparison of Oxalate Oxidase Enzyme Electrodes for Urinary Oxalate Determinations

C.R. BradleyG. A. Rechnitz

Year: 1986 Journal:   Analytical Letters Vol: 19 (1-2)Pages: 151-162   Publisher: Taylor & Francis

Abstract

Abstract Enzyme electrodes for oxalate were constructed by immobilizing oxalate oxidase enzyme (E, C, 1,2,3,4) on both potentiometric carbon dioxide and amperometric hydrogen peroxide sensors. These systems were optimized, and the response characteristics of the two biosensors examined in a comparison study. Areas investigated include linear range, calibration curve slope, response time, limit of detection, and lifetime. Selectivity studies were carried out with the system and showed no measurable response to millimolar levels of various L-amino acids, metal ions or ascorbic acid. This comparison was extended into the choice of an optimal sensor for urinary oxalate determinations with minimal sample pretreatment. The peroxide sensor performed best in urine samples, allowing for the 1:40 dilution necessary to minimize the effect of any interferents present. At this or greater dilution, the recovery of standard additions of oxalate averaged 95.5%, with an average relative standard deviation of 4.9%. The system retained its activity throughout two weeks of continued use.

Keywords:
Chemistry Oxalate Hydrogen peroxide Ascorbic acid Detection limit Oxalic acid Chromatography Amperometry Potentiometric titration Calibration curve Dilution Inorganic chemistry Electrode Biochemistry Electrochemistry

Metrics

17
Cited By
2.31
FWCI (Field Weighted Citation Impact)
9
Refs
0.88
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Citation History

Topics

Electrochemical sensors and biosensors
Physical Sciences →  Engineering →  Electrical and Electronic Engineering
Analytical Chemistry and Sensors
Physical Sciences →  Chemical Engineering →  Bioengineering
Electrochemical Analysis and Applications
Physical Sciences →  Chemistry →  Electrochemistry

Related Documents

JOURNAL ARTICLE

Determination of urinary oxalate with commercially available oxalate oxidase.

J E ButteryN LudvigsenEzio A. BraiottaP R Pannall

Journal:   Clinical Chemistry Year: 1983 Vol: 29 (4)Pages: 700-702
JOURNAL ARTICLE

Determination of urinary oxalate using oxalate-selective membrane electrodes

Raluca‐Ioana Stefan‐van StadenIoana DraghiciGeorge‐Emil Baiulescu

Journal:   Sensors and Actuators B Chemical Year: 2000 Vol: 65 (1-3)Pages: 250-252
JOURNAL ARTICLE

Determination of Urinary Oxalate With Disposable Oxalate Oxidase Hembrane Strips

Kalpana V. InamdarU. TarachandK.G. Raghavan

Journal:   Analytical Letters Year: 1989 Vol: 22 (4)Pages: 841-851
JOURNAL ARTICLE

Quantification of urinary oxalate with oxalate oxidase from beet stems.

D M ObzanskyKurt E. Richardson

Journal:   Clinical Chemistry Year: 1983 Vol: 29 (10)Pages: 1815-1819
© 2026 ScienceGate Book Chapters — All rights reserved.