JOURNAL ARTICLE

Fabrication of multiwalled carbon nanotubes/polyaniline modified Au electrode for ascorbic acid determination

Nidhi ChauhanJagriti NarangC.S. Pundir

Year: 2011 Journal:   The Analyst Vol: 136 (9)Pages: 1938-1938   Publisher: Royal Society of Chemistry

Abstract

An ascorbate oxidase (AsOx) (E.C.1.10.3.3) purified from Lagenaria siceraria fruit was immobilized covalently onto a carboxylated multiwalled carbon nanotubes and polyaniline (c-MWCNT/PANI) layer electrochemically deposited on the surface of an Au electrode. The diffusion coefficient of ascorbic acid was determined as 3.05 × 10(-4) cm(2) s(-1). The behavior of different electrolytes on electro-deposition was also studied. An ascorbate biosensor was fabricated using a AsOx/c-MWCNT/PANI/Au electrode as a working electrode, Ag/AgCl (3 M/saturated KCl) as standard and Pt wire as an auxiliary electrode connected through a potentiostat. Linear range, response time and detection limit were 2-206 μM, 2 s and 0.9 μM respectively. The biosensor showed optimum response at pH 5.8 and in a broader temperature range (30-45 °C), when polarized at +0.6 V. The biosensor was employed for determination of ascorbic acid level in sera, fruit juices and vitamin C tablets. The sensor was evaluated with 91% recovery of added ascorbic acid in sera and 6.5% and 11.4% within and between batch coefficients of variation respectively for five serum samples. There was a good correlation (r = 0.98) between fruit juice ascorbic acid values by the standard 2,6-dichlorophenolindophenol (DCPIP) method and the present method. The enzyme electrode was used 200 times over a period of two months, when stored at 4 °C. The biosensor has advantages over earlier enzyme sensors in that it has no leakage of enzyme, due to the covalent coupling of enzyme with the support, lower response time, wider working range, higher storage stability and no interference by serum substances.

Keywords:
Ascorbic acid Polyaniline Biosensor Electrode Detection limit Chemistry Potentiostat Reference electrode Nuclear chemistry Auxiliary electrode Chromatography Analytical Chemistry (journal) Inorganic chemistry Electrochemistry Electrolyte Organic chemistry Polymerization Biochemistry Polymer

Metrics

97
Cited By
9.70
FWCI (Field Weighted Citation Impact)
42
Refs
0.99
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Citation History

Topics

Electrochemical sensors and biosensors
Physical Sciences →  Engineering →  Electrical and Electronic Engineering
Electrochemical Analysis and Applications
Physical Sciences →  Chemistry →  Electrochemistry
Analytical Chemistry and Sensors
Physical Sciences →  Chemical Engineering →  Bioengineering
© 2026 ScienceGate Book Chapters — All rights reserved.