JOURNAL ARTICLE

Reagentless Amperometric Determination of Hydrogen Peroxide by Silica Sol–Gel Modified Biosensor

Shi Lin ChutJuan Li

Year: 1997 Journal:   The Analyst Vol: 122 (11)Pages: 1431-1434   Publisher: Royal Society of Chemistry

Abstract

A sensitive amperometric hydrogen peroxide biosensor was developed based on the immobilization of horseradish peroxidase (HRP) enzyme by the sol–gel method on a carbon paste electrode in a 'sandwich configuration'. The configuration of the biosensor is a carbon paste/sol–gel–ferrocene/HRP/sol–gel. The biosensor has a fast response with a linear calibration range of 3–57 µmol dm–3 with a sensitivity of 0.067 µA µmol–1 (correlation coefficient 0.996). Based on a signal-to-noise ratio of 3, the detection limit of the biosensor is 0.6 µmol dm–3. The lifetime, fabrication reproducibility and measurement reproducibility were evaluated and an interference study was carried out. Recoveries measured by the biosensor in various samples were satisfactory.

Keywords:
Biosensor Amperometry Horseradish peroxidase Detection limit Reproducibility Hydrogen peroxide Chemistry Chromatography Ferrocene Linear range Analytical Chemistry (journal) Electrode Electrochemistry Organic chemistry Biochemistry

Metrics

86
Cited By
7.29
FWCI (Field Weighted Citation Impact)
16
Refs
0.98
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Citation History

Topics

Electrochemical sensors and biosensors
Physical Sciences →  Engineering →  Electrical and Electronic Engineering
Analytical Chemistry and Sensors
Physical Sciences →  Chemical Engineering →  Bioengineering
Electrochemical Analysis and Applications
Physical Sciences →  Chemistry →  Electrochemistry

Related Documents

JOURNAL ARTICLE

Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide

Juan LiSwee Ngin TanHailin Ge

Journal:   Analytica Chimica Acta Year: 1996 Vol: 335 (1-2)Pages: 137-145
JOURNAL ARTICLE

Australia - Reagentless amperometric biosensor for hydrogen peroxide determination

Journal:   Biosensors and Bioelectronics Year: 1996 Vol: 11 (1-2)Pages: xiv-xv
JOURNAL ARTICLE

Amperometric hydrogen peroxide biosensor with silica sol–gel/chitosan film as immobilization matrix

Yansong MiaoSwee Ngin Tan

Journal:   Analytica Chimica Acta Year: 2001 Vol: 437 (1)Pages: 87-93
JOURNAL ARTICLE

Silica sol–gel immobilized amperometric biosensor for the determination of phenolic compounds

J. LiLian Sai ChiaN.K. GohSwee Ngin Tan

Journal:   Analytica Chimica Acta Year: 1998 Vol: 362 (2-3)Pages: 203-211
JOURNAL ARTICLE

Amperometric Biosensor for Hydrogen Peroxide Based on Sol-Gel/Hydrogel Composite Thin Film

Xu ChenBingquan WangShaojun Dong

Journal:   Electroanalysis Year: 2001 Vol: 13 (14)Pages: 1149-1152
© 2026 ScienceGate Book Chapters — All rights reserved.