JOURNAL ARTICLE

Relaying on sunbury transmission lines

H. H. GreenJ. A. G. OewelOliver Ramsaur

Year: 1949 Journal:   Electrical Engineering Vol: 68 (12)Pages: 1031-1031   Publisher: Institute of Electrical and Electronics Engineers

Abstract

IN PLANNING the development of the transmission facilities needed for the output of the initial installation of two 75,000-kw units at the new Sunbury plant of the Pennsylvania Power and Light Company, provision of "spare" lines has been avoided by placing full dependence on the ability of fast protective and reclosing relaying to reduce line outages to short durations for all except the relatively rare faults that are inherently persistent. Because of this dependence upon modern relaying, the number of lines has been limited to those already existent in close proximity, which are simply being extended into Sunbury, plus three new ones that are required for load-carrying capacity regardless of relaying. (See Figure 1.)

Keywords:
Electric power transmission Spare part Electrical engineering Transmission line Line (geometry) Transmission (telecommunications) Protective relay Engineering Power (physics) Reliability engineering Computer science Electric power system Physics Mechanical engineering

Metrics

0
Cited By
0.00
FWCI (Field Weighted Citation Impact)
0
Refs
0.13
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Topics

Power Systems Fault Detection
Physical Sciences →  Engineering →  Control and Systems Engineering

Related Documents

JOURNAL ARTICLE

Relaying of Transmission Lines from the New Sunbury Generating Station

H. H. GreenJ. A. G. OewelOliver Ramsaur

Journal:   Transactions of the American Institute of Electrical Engineers Year: 1949 Vol: 68 (2)Pages: 873-878
JOURNAL ARTICLE

Protective Relaying for Long Transmission Lines

A. R. C. Van Warrington

Journal:   Transactions of the American Institute of Electrical Engineers Year: 1943 Vol: 62 (6)Pages: 261-268
JOURNAL ARTICLE

Protective relaying (or long transmission lines

A. R. van C. Warrington

Journal:   Electrical Engineering Year: 1943 Vol: 62 (6)Pages: 261-268
JOURNAL ARTICLE

Protective relaying for long transmission lines

Journal:   Electrical Engineering Year: 1943 Vol: 62 (6)Pages: 427-427
JOURNAL ARTICLE

Relaying of High Voltage Interconnection Transmission Lines

H. P. Sleeper

Journal:   Transactions of the American Institute of Electrical Engineers Year: 1933 Vol: 52 (3)Pages: 808-815
© 2026 ScienceGate Book Chapters — All rights reserved.