The components of the cell voltage (viz., anodic potential, drop through the deposit, drop through the electrolyte, and cathodic potential) are discussed for a range of operating conditions and the discussion illustrated with a record of pilot cell data obtained over a period of 32 days of operation. Growth of the deposit was found to occur from the deposit/electrolyte interface and electrical transport through the deposit was by semiconduction.
Kusuhiko TakahashiAkiya Kozawa
Shu-rong DINGXin-hai LIZhixing WangHuajun Guo
Mbuyu Germain NtunkaB.K. Loveday