JOURNAL ARTICLE

O3/H2O2法降解甲基叔丁基醚(MTBE)的试验研究

Abstract

Public health concerns such as multidrug-resistant tuberculosis, bioterrorism, pandemic influenza, and sick building syndrome have brought about increased interest in the use of ultraviolet germicidal irradiation (UVGI) to prevent the spread of airborne infection. UVGI lamps require that radiometric measurements be performed to ensure their safe and effective use. This study evaluates 10 detectors that measure the ultraviolet radiation hazard of low-pressure mercury UVGI lamps, including a polychromator spectroradiometer, narrowband detectors designed to measure the ultraviolet radiation in a short range of wavelengths, and broadband detectors with a varying spectral response designed to follow the UV hazard action spectrum. The angular responses, spectral responses, and linearity of the detectors were measured and compared. The agreement between the measured angular responses and the ideal cosine responses varied widely among the detectors, and in general, the detectors with diffusing optics agreed significantly better with the ideal cosine response. The spectral responses at 254 nm also varied widely among the detectors, and, in general, the narrowband detectors agreed more closely with the 254 nm irradiances measured under the same conditions by a double monochromator spectroradiometer. All detectors displayed good linearity. The angular and spectral response data were then used to develop correction factors for the effective irradiance measurements of two UVGI sources, each measured at 10, 20, and 30 cm. The measured effective irradiances were compared with those measured by a double monochromator spectroradiometer with an integrating sphere input optic. Prior to correction, the effective irradiances measured by the detectors varied widely, ranging from 0.29 to 2.7 times those measured by the spectroradiometer. The application of cosine and spectral response correction factors significantly improved the agreement for the effective irradiances measured by all of the detectors, typically to within 10-20%. Awareness of these detector characteristics can play a key role in ensuring the accuracy of health hazard measurements of UVGI lamps.

Keywords:
Environmental science

Metrics

0
Cited By
0.00
FWCI (Field Weighted Citation Impact)
0
Refs
0.00
Citation Normalized Percentile
Is in top 1%
Is in top 10%

Topics

Oxidative Organic Chemistry Reactions
Physical Sciences →  Chemistry →  Organic Chemistry
Chemical Synthesis and Reactions
Physical Sciences →  Chemistry →  Organic Chemistry

Related Documents

JOURNAL ARTICLE

Chryseobacterium sp.降解β-环糊精包埋的甲基叔丁基醚

欧志龙韩振为张瑞玲李鑫钢黄国强

Journal:   农业环境科学学报 Year: 2007 Vol: 26 (4)Pages: 1459-1463
JOURNAL ARTICLE

零价铁催化降解 2,4-二叔丁基苯酚的试验研究

高乃云刘雪飞周恭明汪琼芳

Journal:   华南理工大学学报(自然科学版) Year: 2016 Vol: 44 (6)
JOURNAL ARTICLE

2,6—二叔丁基对甲酚的毒性实验研究

张东普苏树祥侯永健

Journal:   中华劳动卫生职业病杂志 Year: 1998 Vol: 16 (3)Pages: 174-174
JOURNAL ARTICLE

3,4-亚甲二氧基甲基苯丙胺的开场试验研究

李素霞黄明生王雪

Journal:   Zhonghua xingwei yixue yu naokexue zazhi Year: 2004 Vol: 13 (1)Pages: 26-26
© 2026 ScienceGate Book Chapters — All rights reserved.